DataSave Online

Laboratory parameter recording, reporting and alarm monitoring system

DSO 105 laboratory monitoring and GSM module: black housing, touchscreen with a red frame and an antenna
Continuous monitoring
24 hours a day, 7 days a week
User-defined recording interval
min1 to 99 minutes
System components
10
Touchscreen on every module
4.3 inches

The system

It records, reports and raises the alarm.

DataSave Online continuously monitors, records, and reports key conditions across incubators, cryogenic storage tanks, refrigerators, and essential environmental parameters such as temperature, humidity, and oxygen levels—ensuring 24/7 control and full traceability of critical data.

  • 24/7 continuous monitoring

    Keep critical laboratory data under constant supervision.

  • Instant emergency notifications

    Take rapid action via email, SMS, app notifications, and phone calls.

  • Battery-backed protection

    Supports system reliability during power outages.

  • Advanced reporting

    Easily access all measurement data and generate detailed reports.

System components

Ten components, one system.

DataSave Online provides seamless wired and wireless connectivity over a unified network infrastructure, enabling effortless integration into laboratory environments.

DataSave Online system components

DSO 150 Oxygen/temperature/humidity monitor, front view

Values on the module screens are examples, not measurement results.

DSO 150

Oxygen/temperature/humidity monitor

DSO 150 measures and records oxygen (O₂), temperature, and humidity levels in the laboratory environment in real time via its integrated sensors and enables continuous monitoring.

What it monitors
O₂, temperature and humidity
Sensor
Integrated sensors
O₂ measurement range
0–100%
Temperature measurement range
-40 °C / +80 °C
Humidity measurement range
0–100%
Relay outputs
2 units
Alarm
Two-stage O₂ alarm; temperature and humidity limits

Alarms and notifications

Alarms reach the people who need to know.

In critical situations, the system responds instantly. Automated alerts are delivered through email, SMS, mobile notifications, and voice calls, enabling rapid awareness and immediate action when it matters most.

Notification channels

  • Email
  • SMS
  • Mobile app notification
  • Automated phone call

DSO 105

Laboratory monitoring and GSM module

SIM card support

SMS sending can be performed in alarm situations through the GSM module with SIM card support. Mobile application notifications can be delivered and automatic phone calls can be made, enabling rapid communication with relevant personnel.

Input contacts

The 4 input contacts on the device allow alarm signals from different devices with contact alarm outputs in your laboratory to be integrated into the system. All critical alarms can thus be managed from a single center.

Output contacts

The 2 output contacts operate with on/off logic in alarm scenarios, enabling external devices or warning systems to be triggered.

Alarms and outputs on the modules

  • DSO 130 · Liquid nitrogen tank communication module

    DSO 130 has 2 relay outputs that enable solenoid valves to be triggered according to predefined scenarios. In this way, the solenoid valve on the liquid nitrogen tank’s liquid outlet line can be controlled, allowing liquid nitrogen flow to be managed and automatic filling processes to be supported.

  • DSO 140 · Temperature monitor

    Upper and lower temperature alarm limits can be easily defined by the user via the screen interface. If the temperature goes outside the defined range, the device immediately notifies the user by providing audible and visual alarms.

  • DSO 150 · Oxygen/temperature/humidity monitor

    The device has a two-stage O₂ alarm feature that can be configured by the user in order to keep oxygen levels within safe limits. Two contact outputs are available for first- and second-level alarm scenarios. In addition, the device generates an alarm and notifies the user if temperature and humidity values exceed the limits defined by the user.

  • DSO 153 · Oxygen monitor

    The device has a user-configurable two-stage O₂ alarm feature to ensure oxygen levels are monitored within safe limits. Two contact outputs are available for first- and second-level alarm scenarios.

  • DSO 155 · Temperature & humidity monitor

    In case the alarm limits defined by the user are exceeded, the device provides audible and visual alarms, helping to quickly inform relevant personnel.

DataSave Online

Technical specifications

All modules

External dimensions
170 × 110 × 65 mm
Screen
4.3″ capacitive touch screen
Power
5 V – 1.5 A
Battery backup
Available

DSO 101 · Laboratory variable management software

Recording interval
1–99 min, user-defined
Reports
Graphical or tabular, retrospective
Alarm notifications
Email, SMS, mobile app notifications, automated phone calls

DSO 105 · Laboratory monitoring and GSM module

What it monitors
Connection status of all components
Contact inputs/outputs
4 inputs / 2 outputs
GSM module
SIM card support; SMS in alarm situations

Communication modules

DSO 110

What it monitors
Frozen sample storage tanks
Connection
Communication ports
Input capacity
2 tanks
Witness/reference sensor
2 units · PT100, optional
Compatible control modules
CHART TEC3000 and Vario

DSO 120

What it monitors
Incubator temperature, CO₂ and O₂ data
Connection
Communication ports
Input capacity
2 incubators
Witness/reference sensor
2-2 units · CO₂ and temperature, optional

DSO 130

What it monitors
Level and pressure on pressurized liquid nitrogen tanks
Connection
Sensors with 4–20 mA and 0–10 V outputs
Input capacity
2 tanks
Measurement feature
4–20 mA
Relay outputs
2 units

Monitors

DSO 140

What it monitors
Temperature
Sensor
PT100
Channels
2 independent channels
Relay outputs
2 units
Alarm
Upper and lower limits set on screen; audible and visual alarms

DSO 150

What it monitors
O₂, temperature and humidity
Sensor
Integrated sensors
O₂ measurement range
0–100%
Temperature measurement range
-40 °C / +80 °C
Humidity measurement range
0–100%
Relay outputs
2 units
Alarm
Two-stage O₂ alarm; temperature and humidity limits

DSO 153

What it monitors
O₂
O₂ measurement range
0–100%
Relay outputs
2 units
Alarm
Two-stage O₂ alarm

DSO 155

What it monitors
Temperature and humidity
Temperature measurement range
-40 °C / +80 °C
Humidity measurement range
0–100%
Relay outputs
2 units
Alarm
Audible and visual alarms

DSO 160 · Environmental air quality monitor

What it monitors
Particles and VOC
Relay outputs
2 units

DSO 160 sensors

Particle

Sensor feature
Laser scattering
Air quality classification
ISO CLASS-5, ISO CLASS-6, ISO CLASS-7, ISO CLASS-8, ISO CLASS-9
Units
Particles/m³ – Particles/L
Particle sizes
0.3 µm, 0.5 µm, 1 µm, 5 µm

T-VOC

Sensor feature
MOX-based digital gas sensing technology
Air quality classification
1 (Excellent), 2 (Good), 3 (Moderate), 4 (Poor), 5 (Unhealthy)
Units
ppm – ppb

Get a quote for DataSave Online.