DSO
Laboratory Variables Recording Reporting and Alarm Tracking System
The DataSave Online System, which enables the monitoring of your laboratory variables, is equipped with the most advanced technology. DataSave Online System, which is protected against power cuts thanks to its battery support and can communicate wirelessly or wired over a common network, can continuously record, report, and alarm the variables of your devices such as the culture incubator, frozen sample storage tanks, ovens, refrigerators in your laboratory. It also informs you by sending an e-mail, SMS or calling your emergency phone in case of alarms.

Touch Screen

Battery Support

Alarm System

Data Logger

DSO 101
Laboratory Variables Managing Program
It is the most advanced software system that records and manages the data collected from the modules within the DataSave Online System.
It ensures that the data coming from the modules are collected and recorded in periods of min. 1 and max. 99 minutes, according to the user's preference.
When alarm situations determined by the user occur, it has the feature of sending e-mail, SMS or calling emergency phones according to the notification method preferred by the user.
It allows the recorded data to be reported retrospectively in the form of graphs or tables.
DSO 101
Laboratory Variables Managing Program
It is the most advanced software system that records and manages the data collected from the modules within the DataSave Online System.
It ensures that the data coming from the modules are collected and recorded in periods of min. 1 and max. 99 minutes, according to the user's preference.
When alarm situations determined by the user occur, it has the feature of sending e-mail, SMS or calling emergency phones according to the notification method preferred by the user.
It allows the recorded data to be reported retrospectively in the form of graphs or tables.


DSO 105
Laboratory Control and GSM Module
DSO 105 is the main device of the entire DataSave Online System, which displays whether the components are connected or not, and informs the users in case of alarms.
Thanks to the SIM card to be inserted into the DSO 105 Laboratory Control and GSM Module, it can send SMS and make emergency calls in case of alarms.
It has 7 inputs and 7 contact outputs. In this way, it has the ability to control many features within your laboratory.
TECHNICAL SPECIFICATIONS:
Dimensions |
140 x 240 x 70 mm |
Screen |
4.3’’ Touch Screen |
Power |
13.5 V - 1.5 A- 20 W |
Battery Support |
Yes |
Contact Input/Contact Output |
7 Input/ 7 Output |

DSO 110
Sample Storage Ref. Comm. Module
DSO 110 offers the opportunity to record the tank data by receiving the data via the communication port of your frozen sample storage tanks. Optionally, by adding a PT100 witness/reference temperature sensor, the temperature inside the tank can be measured and recorded instantly.
It can record the data of 2 tanks at the same time. It has the ability to communicate with the heavily preferred CHART Brand TEC3000 and Vario control modules. Please contact for different brands and models of tanks.
TECHNICAL SPECIFICATIONS:
Dimensions |
140 x 240 x 70 mm |
Screen |
4.3’’ Touch Screen |
Power |
13.5 V - 1.5 A- 20 W |
Battery Support |
Yes |
Tank Access Capacity |
2 Pcs. |
Witness Sensor |
Yes- 2 Pcs. |

DSO 120
Embryo/Cell Culture Incubator Comm. Module
DSO 120 Embryo/Cell Culture Incubator of the DataSave Online System is the component used to record temperature, CO2, and O2 data instantly via the communication port. Optionally, CO2 measurement and PT1000 temperature measurement sensor can be added to the module as a witness/reference sensor. In this way, it also allows recording by measuring the CO2 and temperature in your incubator instantly.
DSO 120 can record the data of 2 incubators at the same time. It is capable of communicating with THERMO SCIENTIFIC Brand Heracell Series, Forma SteriCycle Series, K-Systems G185/G210 model desktop incubators, and GS Biotech Brand incubator communication ports, which are heavily preferred. Please contact for different brands and models of tanks.
TECHNICAL SPECIFICATIONS:
Dimensions |
140 x 240 x 70 mm |
Screen |
4.3’’ Touch Screen |
Power |
13.5 V - 1.5 A- 20 W |
Battery Support |
Yes |
Incubator Access Capacity |
2 Pcs. |
Witness Sensor-CO2 |
Optional-2 Pcs. |
Witness Sensör-PT1000 |
Optional -2 Pcs. |

DSO 130
LN2 Tank Communication Module
DSO 130 offers the opportunity to record and monitor the data coming from the level and pressure sensors with 4-20mA output on your Pressurized Liquid Nitrogen Tanks.
DSO 130 allows for recording data of 2 liquid nitrogen tanks at the same time. Thanks to the 2 relay outputs it contains, it is capable of triggering solenoid valves through predetermined scenarios. In order to be able to fill in this way, it allows you to control the liquid nitrogen flow by controlling the solenoid valve on the liquid outlet line of your liquid nitrogen tank.
TECHNICAL SPECIFICATIONS:
Dimensions |
140 x 210 x 70 mm |
Screen |
4.3’’ Touch Screen |
Power |
13.5 V - 1.5 A- 20 W |
Battery Support |
Yes |
Tank Access Capacity |
2 Pcs. |
Measurement Feature |
4-20 mA |
Relay Output |
2 Pcs. - 24V DC |

DSO 140
Temperature Monitor
DSO 140 records and monitors the temperature in Ovens, Refrigerators, and Frozen Sample Storage Tanks by measuring instantly via the PT100 sensor. Thanks to its multi-point calibration feature, it allows reliable use.
Low temperature and high-temperature points can be determined from the 4.3'' touch screen interface, and if the taken measurement is outside of these bands determined by the user, the device gives an audible and visual alarm.
TECHNICAL SPECIFICATIONS:
Dimensions |
140 x 240 x 70 mm |
Screen |
4.3’’ Touch Screen |
Power |
13.5 V - 1.5 A- 20 W |
Battery Support |
Yes |
Incubator Access Capacity |
2 Pcs. |
Witness Sensor-CO2 |
Optional-2 Pcs. |
Witness Sensör-PT1000 |
Optional -2 Pcs. |

DSO 150
O2/Temperature/Humidity Monitor
DSO150 measures and records the level of O2, tem- perature, and humidity in the laboratory environment through the sensors it contains and monitors these data.
It includes a two-stage O2 level alarm feature that can be changed by the user for the ideal determination of the O2 level. It has 2 relay outputs for a two-stage (first and second level) alarm.
TECHNICAL SPECIFICATIONS:
Dimensions |
140 x 210 x 70 mm |
Screen |
4.3’’ Touch Screen |
Power |
13.5 V - 1.5 A- 20 W |
Battery Support |
Yes |
O2 Measurement Range |
0-100 % |
Temp. Measurement Range |
-40 oC / +80 oC |
Hum. Measurement Range |
0-100 % |

DSO 153
O2 Monitor
DSO 153 offers the opportunity to instantly measure the ambient oxygen level in IVF and Stem Cell Culture Laboratories and to monitor these data. In this way, it informs the user and creates traceability by providing historical reporting of recorded variables.

DSO 155
Temperature/Humidity Monitor
DSO 155 offers the opportunity to measure ambient temperature and humidity in IVF and Stem Cell Culture Laboratories and to monitor these data. In this way, it informs the user and creates traceability by providing historical reporting of recorded variables.
Monitor with DSO
Your Laboratory Variables
The DataSave Online System continuously monitors your laboratory equipment and instantly notifies you via email, SMS, or phone in case of any irregularity.
The BTH 20 heating chamber provides 2-dimensional heating thanks to the heater film resistor. The film resistance that heats the bottom and side surfaces is controlled by the PT100 Sensor, and the most precise control is provided on the heating surface.
Other Documents